Top header photo
 Trainiax logo
HomeNew Contact Links

Undecorated Drawings - CEI

Selected Scales: 1:181:361:55

See the Locomotive Phases section for phase descriptions.

1:18 Drawings

Number of Drawings: 12

Model Built Phase Numbers Notes Last modified
EMD GP30
  
1963-06 2a CEI 239-241
2019-07-31Revision history:

2019-07-31
- Relocated front hood seam resulting in revised hood proportions
- Front section of hood lengthened and blower duct widened by 1"
- Gap from seam to middle hood doors narrowed by 0.75"
- Middle hood doors narrowed by 0.25"
- Increased height of walkway blower duct and bottom of hood doors
EMD GP35
  
1964-03 1a1 CEI 244
2019-01-21Revision history:

2019-01-18
- Relocated front hood seam resulting in revised hood proportions
- Front section of hood lengthened and blower duct widened by 1"
- Gap from seam to middle hood doors shortened by 0.75"
- Middle hood doors shortened by 0.25"
- Increased height of walkway blower duct and bottom of hood doors
- Corrected seam at bottom corners of long hood
EMD GP35
  
1964-03 1a2 CEI 242-243
2019-01-21Revision history:

2019-01-18
- Relocated front hood seam resulting in revised hood proportions
- Front section of hood lengthened and blower duct widened by 1"
- Gap from seam to middle hood doors shortened by 0.75"
- Middle hood doors shortened by 0.25"
- Increased height of walkway blower duct and bottom of hood doors
- Corrected seam at bottom corners of long hood
EMD GP35
  
1964-06 -
1964-07
1b1 CEI 245-254
2019-01-21Revision history:

2019-01-18
- Relocated front hood seam resulting in revised hood proportions
- Front section of hood lengthened and blower duct widened by 1"
- Gap from seam to middle hood doors shortened by 0.75"
- Middle hood doors shortened by 0.25"
- Increased height of walkway blower duct and bottom of hood doors
- Corrected seam at bottom corners of long hood
EMD GP35
  
1964-09 -
1964-11
1b3 CEI 255-264
2019-01-21Revision history:

2019-01-18
- Relocated front hood seam resulting in revised hood proportions
- Front section of hood lengthened and blower duct widened by 1"
- Gap from seam to middle hood doors shortened by 0.75"
- Middle hood doors shortened by 0.25"
- Increased height of walkway blower duct and bottom of hood doors
- Corrected seam at bottom corners of long hood
EMD GP35
  
1965-06 2b CEI 365-272
2019-08-07Revision history:

2019-01-18
- Relocated front hood seam resulting in revised hood proportions
- Front section of hood lengthened and blower duct widened by 1"
- Gap from seam to middle hood doors shortened by 0.75"
- Middle hood doors shortened by 0.25"
- Increased height of walkway blower duct and bottom of hood doors
- Corrected seam at bottom corners of long hood

2019-08-07
- Corrected line/crop issue at right of image