![Trainiax logo](layout/trainiax-logo.png)
Undecorated Drawings - EMD GP38-3
Selected scales: |
1:18 Drawings
Model | Built | Phase | Numbers | Notes | Last modified |
---|---|---|---|---|---|
EMD GP38-3 ← → | FWWR 2000 | GP35 rebuild (nee DRGW 3038) | 2023-12-28Revision history:
2019-07-23 - Relocated front hood seam resulting in revised hood proportions - Front section of hood lengthened and blower duct widened by 1" - Gap from seam to middle hood doors shortened by 0.75" - Middle hood doors shortened by 0.25" - Increased height of walkway blower duct and bottom of hood doors - Corrected seam at bottom corners of long hood - Revised paper air filter housing and dynamic brake taper - Corrected minor line glitch on latches on first engine room door 2020-12-09 - Increased handrail thickness - Revised radiator and dynamic brake fans (48" fans) 2022-02-08 - Coupler cut lever and pilot details - Corner handrail end plate / stairwell attachment points - Dynamic brake housing dimensions and shape - Added missing portion of #2 (left side) and #3 (right side) traction motor air ducts 2023-12-28 - Nathan P-series horn dimensions | ||
EMD GP38-3 ← → | FWWR 2001 | GP35 rebuild (nee DRGW 3050) | 2023-12-28Revision history:
2019-07-23 - Relocated front hood seam resulting in revised hood proportions - Front section of hood lengthened and blower duct widened by 1" - Gap from seam to middle hood doors shortened by 0.75" - Middle hood doors shortened by 0.25" - Increased height of walkway blower duct and bottom of hood doors - Corrected seam at bottom corners of long hood - Revised paper air filter housing and dynamic brake taper - Corrected minor line glitch on latches on first engine room door 2020-12-09 - Increased handrail thickness - Revised radiator and dynamic brake fans (48" fans) 2022-02-08 - Coupler cut lever and pilot details - Corner handrail end plate / stairwell attachment points - Dynamic brake housing dimensions and shape - Added missing portion of #2 (left side) and #3 (right side) traction motor air ducts 2023-12-28 - Nathan P-series horn dimensions | ||
EMD GP38-3 ← → | FWWR 2002 | GP35 rebuild (nee DRGW 3035) | 2023-12-28Revision history:
2019-07-23 - Relocated front hood seam resulting in revised hood proportions - Front section of hood lengthened and blower duct widened by 1" - Gap from seam to middle hood doors shortened by 0.75" - Middle hood doors shortened by 0.25" - Increased height of walkway blower duct and bottom of hood doors - Corrected seam at bottom corners of long hood - Revised paper air filter housing and dynamic brake taper - Corrected minor line glitch on latches on first engine room door 2020-12-09 - Increased handrail thickness - Revised radiator and dynamic brake fans (48" fans) 2022-02-08 - Coupler cut lever and pilot details - Corner handrail end plate / stairwell attachment points - Dynamic brake housing dimensions and shape - Added missing portion of #2 (left side) and #3 (right side) traction motor air ducts 2023-12-28 - Nathan P-series horn dimensions | ||
EMD GP38-3 ← → | FWWR 2003 | GP35 rebuild (nee SP 7753) | 2023-12-28Revision history:
2019-07-23 - Relocated front hood seam resulting in revised hood proportions - Front section of hood lengthened and blower duct widened by 1" - Gap from seam to middle hood doors shortened by 0.75" - Middle hood doors shortened by 0.25" - Increased height of walkway blower duct and bottom of hood doors - Corrected seam at bottom corners of long hood - Revised paper air filter housing and dynamic brake taper - Corrected minor line glitch on latches on first engine room door 2020-12-09 - Increased handrail thickness - Revised radiator and dynamic brake fans (48" fans) 2022-02-08 - Coupler cut lever and pilot details - Corner handrail end plate / stairwell attachment points - Dynamic brake housing dimensions and shape - Added missing portion of #2 (left side) and #3 (right side) traction motor air ducts 2023-12-28 - Nathan P-series horn dimensions | ||
EMD GP38-3 ← → | FWWR 2004-2005 | GP38 rebuild (nee PC 7922, 7696) | 2022-03-03Revision history:
2019-07-23 - Relocated front hood seam resulting in revised hood proportions - Front section of hood lengthened and blower duct widened by 1" - Gap from seam to middle hood doors shortened by 0.75" - Middle hood doors shortened by 0.25" - Increased height of walkway blower duct and bottom of hood doors - Corrected seam at bottom corners of long hood - Revised paper air filter housing and dynamic brake taper - Corrected minor line glitch on latches on first engine room door - Revised radiator intake grills and roof fan hatch - Revised handrail stanchion spacing - Fuel tank and air reservoirs moved 1" to 1.5" rearward 2020-12-09 - Increased handrail thickness - Revised radiator fan dimensions and spacing - Fuel tank vent pipe (increased diameter, revised fittings) - Added missing pixel in left side frame above rear of fuel tank 2021-01-09 - Fuel tank height and gap from underframe 2022-02-08 - Coupler cut lever and pilot details - Corner handrail end plate / stairwell attachment points 2022-03-03 - Horn manifold and back cap dimensions | ||
EMD GP38-3 ← → | 2004-02 (R) | 1 | NS 5801 | NS GP50 rebuild | 2023-12-28Revision history:
2019-08-06 - Revised center hood door spacing - Revised hood behind cab - Blower duct widened by 1" (Phase 1 versions) - Increased height of walkway blower duct and bottom of hood doors - Corrected minor line glitch on latches on first engine room door 2020-12-11 - Revised side handrail stanchions - Increased handrail thickness - Revised radiator and dynamic brake fan dimensions and spacing - Fuel tank vent pipe (increased diameter, revised fittings) - Air pipe vent valve (left front / right rear under walkway) 2021-01-12 - Fuel tank height and gap from underframe 2022-11-30 - Coupler cut lever and pilot details - Corner handrail end plate / stairwell attachment points - Revised ribs on blower duct 2022-12-21 - End handrail height 2023-12-28 - Nathan P-series horn dimensions |
EMD GP38-3 ← → | 2004-06 - 2005-06 (R) | 2 | NS 5802-5808, 5811-5813 | " | 2022-12-21Revision history:
2019-08-06 - Revised center hood door spacing - Revised hood behind cab - Blower duct widened by 1" (Phase 1 versions) - Increased height of walkway blower duct and bottom of hood doors - Corrected minor line glitch on latches on first engine room door 2020-12-11 - Revised side handrail stanchions - Increased handrail thickness - Revised radiator and dynamic brake fan dimensions and spacing - Fuel tank vent pipe (increased diameter, revised fittings) - Air pipe vent valve (left front / right rear under walkway) 2021-01-12 - Fuel tank height and gap from underframe 2022-11-30 - Coupler cut lever and pilot details - Corner handrail end plate / stairwell attachment points - Revised ribs on blower duct 2022-12-21 - End handrail height |
EMD GP38-3 ← → | 2004-12 - 2005-06 (R) | " | NS 5809-5810, 5814 | " | 2022-12-21Revision history:
2019-08-06 - Revised center hood door spacing - Revised hood behind cab - Blower duct widened by 1" (Phase 1 versions) - Increased height of walkway blower duct and bottom of hood doors - Corrected minor line glitch on latches on first engine room door 2020-12-11 - Revised side handrail stanchions - Increased handrail thickness - Revised radiator and dynamic brake fan dimensions and spacing - Fuel tank vent pipe (increased diameter, revised fittings) - Air pipe vent valve (left front / right rear under walkway) 2021-01-12 - Fuel tank height and gap from underframe 2022-11-30 - Coupler cut lever and pilot details - Corner handrail end plate / stairwell attachment points - Revised ribs on blower duct 2022-12-21 - End handrail height |
EMD GP38-3 ← → | 2005-07 - 2005-09 (R) | 3 | NS 5815-5817, 5819 | " | 2022-12-21Revision history:
2019-08-06 - Revised center hood door spacing - Revised hood behind cab - Blower duct widened by 1" (Phase 1 versions) - Increased height of walkway blower duct and bottom of hood doors - Corrected minor line glitch on latches on first engine room door 2020-12-11 - Revised side handrail stanchions - Increased handrail thickness - Revised radiator and dynamic brake fan dimensions and spacing - Fuel tank vent pipe (increased diameter, revised fittings) - Air pipe vent valve (left front / right rear under walkway) 2021-01-12 - Fuel tank height and gap from underframe 2022-11-30 - Coupler cut lever and pilot details - Corner handrail end plate / stairwell attachment points - Revised ribs on blower duct 2022-12-21 - End handrail height |
EMD GP38-3 ← → | 2005-09 (R) | " | NS 5818 | " | 2023-12-28Revision history:
2019-08-06 - Revised center hood door spacing - Revised hood behind cab - Blower duct widened by 1" (Phase 1 versions) - Increased height of walkway blower duct and bottom of hood doors - Corrected minor line glitch on latches on first engine room door 2020-12-11 - Revised side handrail stanchions - Increased handrail thickness - Revised radiator and dynamic brake fan dimensions and spacing - Fuel tank vent pipe (increased diameter, revised fittings) - Air pipe vent valve (left front / right rear under walkway) 2021-01-12 - Fuel tank height and gap from underframe 2022-11-30 - Coupler cut lever and pilot details - Corner handrail end plate / stairwell attachment points - Revised ribs on blower duct 2022-12-21 - End handrail height 2023-12-28 - Nathan P-series horn dimensions |
EMD GP38-3 ← → | 2006-11 - 2006-12 (R) | 4 | NS 5820, 5823 | " | 2022-12-21Revision history:
2019-08-06 - Revised center hood door spacing - Revised hood behind cab - Blower duct widened by 1" (Phase 1 versions) - Increased height of walkway blower duct and bottom of hood doors - Corrected minor line glitch on latches on first engine room door 2020-12-11 - Revised side handrail stanchions - Increased handrail thickness - Revised radiator and dynamic brake fan dimensions and spacing - Fuel tank vent pipe (increased diameter, revised fittings) - Air pipe vent valve (left front / right rear under walkway) 2021-01-12 - Fuel tank height and gap from underframe 2022-11-30 - Coupler cut lever and pilot details - Corner handrail end plate / stairwell attachment points - Revised ribs on blower duct 2022-12-21 - End handrail height |
EMD GP38-3 ← → | 2006-12 (R) | " | NS 5821 | " | 2022-12-21Revision history:
2019-08-06 - Revised center hood door spacing - Revised hood behind cab - Blower duct widened by 1" (Phase 1 versions) - Increased height of walkway blower duct and bottom of hood doors - Corrected minor line glitch on latches on first engine room door 2020-12-11 - Revised side handrail stanchions - Increased handrail thickness - Revised radiator and dynamic brake fan dimensions and spacing - Fuel tank vent pipe (increased diameter, revised fittings) - Air pipe vent valve (left front / right rear under walkway) 2021-01-12 - Fuel tank height and gap from underframe 2022-11-30 - Coupler cut lever and pilot details - Corner handrail end plate / stairwell attachment points - Revised ribs on blower duct 2022-12-21 - End handrail height |
EMD GP38-3 ← → | 2006-12 (R) | " | NS 5822 | " | 2022-12-21Revision history:
2019-08-06 - Revised center hood door spacing - Revised hood behind cab - Blower duct widened by 1" (Phase 1 versions) - Increased height of walkway blower duct and bottom of hood doors - Corrected minor line glitch on latches on first engine room door 2020-12-11 - Revised side handrail stanchions - Increased handrail thickness - Revised radiator and dynamic brake fan dimensions and spacing - Fuel tank vent pipe (increased diameter, revised fittings) - Air pipe vent valve (left front / right rear under walkway) 2021-01-12 - Fuel tank height and gap from underframe 2022-11-30 - Coupler cut lever and pilot details - Corner handrail end plate / stairwell attachment points - Revised ribs on blower duct 2022-12-21 - End handrail height |
EMD GP38-3 ← → | 2006-12 - 2007-01 (R) | " | NS 5824-5829 | " | 2022-12-21Revision history:
2019-08-06 - Revised center hood door spacing - Revised hood behind cab - Blower duct widened by 1" (Phase 1 versions) - Increased height of walkway blower duct and bottom of hood doors - Corrected minor line glitch on latches on first engine room door 2020-12-11 - Revised side handrail stanchions - Increased handrail thickness - Revised radiator and dynamic brake fan dimensions and spacing - Fuel tank vent pipe (increased diameter, revised fittings) - Air pipe vent valve (left front / right rear under walkway) 2021-01-12 - Fuel tank height and gap from underframe 2022-11-30 - Coupler cut lever and pilot details - Corner handrail end plate / stairwell attachment points - Revised ribs on blower duct 2022-12-21 - End handrail height |
EMD GP38-3 ← → | 2007-02 - 2007-04 (R) | 5 | NS 5830-5834, 5836-5837 | " | 2022-12-21Revision history:
2019-08-06 - Revised center hood door spacing - Revised hood behind cab - Blower duct widened by 1" (Phase 1 versions) - Increased height of walkway blower duct and bottom of hood doors - Corrected minor line glitch on latches on first engine room door 2020-12-11 - Revised side handrail stanchions - Increased handrail thickness - Revised radiator and dynamic brake fan dimensions and spacing - Fuel tank vent pipe (increased diameter, revised fittings) - Air pipe vent valve (left front / right rear under walkway) 2021-01-12 - Fuel tank height and gap from underframe 2022-11-30 - Coupler cut lever and pilot details - Corner handrail end plate / stairwell attachment points - Revised ribs on blower duct 2022-12-21 - End handrail height |
EMD GP38-3 ← → | 2007-03 (R) | " | NS 5835 | " | 2022-12-21Revision history:
2019-08-06 - Revised center hood door spacing - Revised hood behind cab - Blower duct widened by 1" (Phase 1 versions) - Increased height of walkway blower duct and bottom of hood doors - Corrected minor line glitch on latches on first engine room door 2020-12-11 - Revised side handrail stanchions - Increased handrail thickness - Revised radiator and dynamic brake fan dimensions and spacing - Fuel tank vent pipe (increased diameter, revised fittings) - Air pipe vent valve (left front / right rear under walkway) 2021-01-12 - Fuel tank height and gap from underframe 2022-11-30 - Coupler cut lever and pilot details - Corner handrail end plate / stairwell attachment points - Revised ribs on blower duct 2022-12-21 - End handrail height |
See also: