Undecorated Drawings - EMD GP38AC
Selected scales: |
1:18 Drawings
Model | Built | Phase | Numbers | Notes | Last modified |
---|---|---|---|---|---|
EMD GP38AC ← → | 1970-04 - 1970-05 | 2b | DTI 210-217 | 215-217 re# 207-209 (reverse) | 2022-01-28Revision history:
2016-10-19 - Corrected Nathan M3 horn 2018-12-01 - Corrected minor line glitch on latches on first engine room door 2019-01-18 - Relocated front hood seam resulting in revised hood proportions - Front section of hood lengthened and blower duct widened by 1" - Gap from seam to middle hood doors shortened by 0.75" - Middle hood doors shortened by 0.25" - Increased height of walkway blower duct and bottom of hood doors - Corrected seam at bottom corners of long hood - Revised radiator intake grills and roof fan hatch - Revised paper air filter housing 2019-01-23 - Revised handrail stanchion spacing - Fuel tank and air reservoirs moved 1" to 1.5" rearward 2020-12-04 - Increased handrail thickness - Revised radiator fan dimensions and spacing - Fuel tank vent pipe (increased diameter, revised fittings) - Added missing pixel in left side frame above rear of fuel tank 2021-01-09 - Fuel tank height and gap from underframe 2022-01-29 - Coupler cut lever and pilot details - Corner handrail end plate / stairwell attachment points |
EMD GP38AC ← → | 1971-07 | 2c | DTI 215-220 | 2022-01-29Revision history:
2016-10-19 - Corrected Nathan M3 horn 2018-12-01 - Corrected minor line glitch on latches on first engine room door 2019-01-18 - Relocated front hood seam resulting in revised hood proportions - Front section of hood lengthened and blower duct widened by 1" - Gap from seam to middle hood doors shortened by 0.75" - Middle hood doors shortened by 0.25" - Increased height of walkway blower duct and bottom of hood doors - Corrected seam at bottom corners of long hood - Revised radiator intake grills and roof fan hatch - Revised paper air filter housing 2019-01-23 - Fuel tank and air reservoirs moved 1" to 1.5" rearward 2020-12-04 - Revised side handrail stanchions - Increased handrail thickness - Revised radiator fan dimensions and spacing - Fuel tank vent pipe (increased diameter, revised fittings) 2021-01-09 - Fuel tank height and gap from underframe 2022-01-29 - Coupler cut lever and pilot details - Corner handrail end plate / stairwell attachment points - Revised ribs on blower duct | |
EMD GP38AC ← → | 1971-03 - 1971-12 | 2c, 3 | GMO 721-733 | 2022-03-02Revision history:
2019-01-18 - Relocated front hood seam resulting in revised hood proportions - Front section of hood lengthened and blower duct widened by 1" - Gap from seam to middle hood doors shortened by 0.75" - Middle hood doors shortened by 0.25" - Increased height of walkway blower duct and bottom of hood doors - Corrected seam at bottom corners of long hood - Revised radiator intake grills and roof fan hatch - Revised paper air filter housing 2019-01-23 - Fuel tank and air reservoirs moved 1" to 1.5" rearward - Corrected pipe overlapping bell 2020-12-04 - Revised side handrail stanchions - Increased handrail thickness - Revised radiator fan dimensions and spacing - Fuel tank vent pipe (increased diameter, revised fittings) 2021-01-09 - Fuel tank height and gap from underframe 2022-01-29 - Coupler cut lever and pilot details - Corner handrail end plate / stairwell attachment points - Revised ribs on blower duct 2022-03-02 - Horn manifold and back cap dimensions | |
EMD GP38AC ← → | 1971-11 | 3 | GTW 5800-5811 | 2022-01-29Revision history:
2019-01-18 - Relocated front hood seam resulting in revised hood proportions - Front section of hood lengthened and blower duct widened by 1" - Gap from seam to middle hood doors shortened by 0.75" - Middle hood doors shortened by 0.25" - Increased height of walkway blower duct and bottom of hood doors - Corrected seam at bottom corners of long hood - Revised radiator intake grills and roof fan hatch - Revised paper air filter housing 2019-01-23 - Fuel tank and air reservoirs moved 1" to 1.5" rearward - Corrected pipe overlapping bell 2019-01-31 - Added missing snow shields 2020-12-04 - Revised side handrail stanchions - Increased handrail thickness - Revised radiator fan dimensions and spacing - Fuel tank vent pipe (increased diameter, revised fittings) 2021-01-09 - Fuel tank height and gap from underframe 2022-01-29 - Coupler cut lever and pilot details - Corner handrail end plate / stairwell attachment points - Revised ribs on blower duct | |
EMD GP38AC ← → | 1970-02 | 2b | IC 9500-9519 | 2022-03-02Revision history:
2019-01-18 - Relocated front hood seam resulting in revised hood proportions - Front section of hood lengthened and blower duct widened by 1" - Gap from seam to middle hood doors shortened by 0.75" - Middle hood doors shortened by 0.25" - Increased height of walkway blower duct and bottom of hood doors - Corrected seam at bottom corners of long hood - Revised radiator intake grills and roof fan hatch - Revised paper air filter housing and dynamic brake taper 2019-01-23 - Revised handrail stanchion spacing - Fuel tank and air reservoirs moved 1" to 1.5" rearward 2020-05-16 - Added ATS shoe on the right front axle - Revised cab side mirrors - Added water level sight glass (right side) 2020-12-04 - Increased handrail thickness - Revised radiator fan dimensions and spacing - Fuel tank vent pipe (increased diameter, revised fittings) - Added missing pixel in left side frame above rear of fuel tank 2021-01-09 - Fuel tank height and gap from underframe 2022-01-29 - Coupler cut lever and pilot details - Corner handrail end plate / stairwell attachment points 2022-03-02 - Horn manifold and back cap dimensions | |
EMD GP38AC ← → | 1971-05 - 1971-07 | 2c | LN 4020-4049 | 2022-01-29Revision history:
2018-12-01 - Corrected minor line glitch on latches on first engine room door 2019-01-18 - Relocated front hood seam resulting in revised hood proportions - Front section of hood lengthened and blower duct widened by 1" - Gap from seam to middle hood doors shortened by 0.75" - Middle hood doors shortened by 0.25" - Increased height of walkway blower duct and bottom of hood doors - Corrected seam at bottom corners of long hood - Revised radiator intake grills and roof fan hatch - Revised paper air filter housing and dynamic brake taper 2019-01-23 - Fuel tank and air reservoirs moved 1" to 1.5" rearward - Corrected pipe overlapping bell 2020-12-04 - Revised side handrail stanchions - Increased handrail thickness - Revised radiator fan dimensions and spacing - Fuel tank vent pipe (increased diameter, revised fittings) 2021-01-09 - Fuel tank height and gap from underframe 2022-01-29 - Coupler cut lever and pilot details - Corner handrail end plate / stairwell attachment points - Revised ribs on blower duct | |
EMD GP38AC ← → | 1971-12 | 3 | LV 310-313 | 2022-03-02Revision history:
2018-12-01 - Corrected minor line glitch on latches on first engine room door 2019-01-18 - Relocated front hood seam resulting in revised hood proportions - Front section of hood lengthened and blower duct widened by 1" - Gap from seam to middle hood doors shortened by 0.75" - Middle hood doors shortened by 0.25" - Increased height of walkway blower duct and bottom of hood doors - Corrected seam at bottom corners of long hood - Revised radiator intake grills and roof fan hatch - Revised paper air filter housing and dynamic brake taper 2019-01-23 - Fuel tank and air reservoirs moved 1" to 1.5" rearward - Corrected pipe overlapping bell 2020-12-04 - Revised side handrail stanchions - Increased handrail thickness - Revised radiator fan dimensions and spacing - Fuel tank vent pipe (increased diameter, revised fittings) 2021-01-09 - Fuel tank height and gap from underframe 2022-01-29 - Coupler cut lever and pilot details - Corner handrail end plate / stairwell attachment points - Revised ribs on blower duct 2022-03-02 - Horn manifold and back cap dimensions | |
EMD GP38AC ← → | 1971-06 - 1971-12 | 2c | NW 4100-4159 | High short hood | 2022-03-02Revision history:
2017-05-16 - Added grabiron at top of short hood 2018-12-01 - Corrected minor line glitch on latches on first engine room door 2019-01-18 - Relocated front hood seam resulting in revised hood proportions - Front section of hood lengthened and blower duct widened by 1" - Gap from seam to middle hood doors shortened by 0.75" - Middle hood doors shortened by 0.25" - Increased height of walkway blower duct and bottom of hood doors - Corrected seam at bottom corners of long hood - Revised radiator intake grills and roof fan hatch - Revised paper air filter housing and dynamic brake taper 2019-01-23 - Fuel tank and air reservoirs moved 1" to 1.5" rearward 2019-08-10 - Corrected glitch in short hood headlight 2020-12-04 - Revised side handrail stanchions - Increased handrail thickness - Revised radiator fan dimensions and spacing - Fuel tank vent pipe (increased diameter, revised fittings) 2021-01-09 - Fuel tank height and gap from underframe 2022-01-29 - Coupler cut lever and pilot details - Corner handrail end plate / stairwell attachment points - Revised ribs on blower duct 2022-03-02 - Horn manifold and back cap dimensions |
EMD GP38AC ← → | 1971-02 - 1971-03 | 2b | SLSF 633-653 | 2022-03-02Revision history:
2018-12-01 - Corrected minor line glitch on latches on first engine room door 2019-01-18 - Relocated front hood seam resulting in revised hood proportions - Front section of hood lengthened and blower duct widened by 1" - Gap from seam to middle hood doors shortened by 0.75" - Middle hood doors shortened by 0.25" - Increased height of walkway blower duct and bottom of hood doors - Corrected seam at bottom corners of long hood - Revised radiator intake grills and roof fan hatch - Revised paper air filter housing and dynamic brake taper 2019-01-23 - Revised handrail stanchion spacing - Fuel tank and air reservoirs moved 1" to 1.5" rearward - Corrected pipe overlapping bell 2020-12-04 - Increased handrail thickness - Revised radiator fan dimensions and spacing - Fuel tank vent pipe (increased diameter, revised fittings) - Added missing pixel in left side frame above rear of fuel tank 2021-01-09 - Fuel tank height and gap from underframe 2022-01-05 - Corrected line glitch in sand hose ahead of fuel tank (left side) 2022-01-29 - Coupler cut lever and pilot details - Corner handrail end plate / stairwell attachment points 2022-03-02 - Horn manifold and back cap dimensions | |
EMD GP38AC ← → | 1971-04 | 2c | SLSF 654-662 | 2022-03-02Revision history:
2018-12-01 - Corrected minor line glitch on latches on first engine room door 2019-01-18 - Relocated front hood seam resulting in revised hood proportions - Front section of hood lengthened and blower duct widened by 1" - Gap from seam to middle hood doors shortened by 0.75" - Middle hood doors shortened by 0.25" - Increased height of walkway blower duct and bottom of hood doors - Corrected seam at bottom corners of long hood - Revised radiator intake grills and roof fan hatch - Revised paper air filter housing and dynamic brake taper 2019-01-23 - Fuel tank and air reservoirs moved 1" to 1.5" rearward - Corrected pipe overlapping bell 2020-12-04 - Revised side handrail stanchions - Increased handrail thickness - Revised radiator fan dimensions and spacing - Fuel tank vent pipe (increased diameter, revised fittings) 2021-01-09 - Fuel tank height and gap from underframe 2022-01-05 - Corrected line glitch in sand hose ahead of fuel tank (left side) 2022-01-29 - Coupler cut lever and pilot details - Corner handrail end plate / stairwell attachment points - Revised ribs on blower duct 2022-03-02 - Horn manifold and back cap dimensions | |
EMD GP38AC ← → | 1971-04 - 1971-10 | 2c | SOU 2823-2878 | High short hood | 2022-01-29Revision history:
2020-01-11 - Added stepwell lights - Lowered flag holder (right side) 2020-12-04 - Revised side handrail stanchions - Increased handrail thickness - Revised radiator fan dimensions and spacing - Fuel tank vent pipe (increased diameter, revised fittings) 2021-01-09 - Fuel tank height and gap from underframe 2022-01-29 - Coupler cut lever and pilot details - Corner handrail end plate / stairwell attachment points - Revised ribs on blower duct |
See also: